When replacing a failed fan tray in a running system, be sure to promptly replace the fan tray.
Note
If one or more fans fail within a fan tray, the Fan Status LED turns red. A fan failure could lead to
temperature alarms if not corrected immediately.
Tip
The fan status is continuously monitored by the software. In case of a fan failure, the following actions occur:
•
System messages are displayed.
•
Call Home alerts are sent (if configured).
•
SNMP notifications are sent (if configured).
To display the fan module statuses, see
Displaying the Status for the Fan Trays, on page 58
.
The fan trays fill slots 41 (labeled as FAN 1), 42 (labeled as FAN 2), and 43 (labeled as 43) in the chassis.
Note
Displaying the Status for the Fan Trays
You can display the status of the fan trays by using the
show environment fan
command.
switch#
show environment fan
Fan:
------------------------------------------------------
Fan
Model
Hw
Status
------------------------------------------------------
Fan1(sys_fan1)
N9K-C9504-FAN
0.5020
Ok
Fan2(sys_fan2)
N9K-C9504-FAN
0.5020
Ok
Fan3(sys_fan3)
N9K-C9504-FAN
0.5010
Ok
Fan_in_PS1
--
--
Ok
Fan_in_PS2
--
--
None
Fan_in_PS3
--
--
None
Fan_in_PS4
--
--
None
Fan Zone Speed: Zone 1: 0x0
Fan Air Filter : NotSupported
switch#