Troubleshooting
Free Bound Virtualized Storage when the Master System Fails
Cisco Small Business NSS2000 Series Administration Guide
155
A
STEP 2
Go through the steps to upgrade the firmware ensuring that the conditions listed
previously are met.
Free Bound Virtualized Storage when the Master System Fails
Problem Scenario: A storage system is bound to a failed storage system and
rejects any bind requests from other systems. The steps to recreate this problem
are as follows:
STEP 1
Export storage from System A.
STEP 2
Import storage from System A to System B.
STEP 3
System B crashes and cannot be recovered.
STEP 4
System A is "bound" to System B and rejects any new bind requests from other
systems.
Resolution: To resolve the problem:
STEP 1
Unexport the bound storage system (in our example, System A).
STEP 2
Re-export the storage system.
The storage system is now available to be used by another system.
All CIFS Connections were Unexpectedly Ended
Problem: All current CIFS connections to the NSS were unexpectedly severed.
Solution: Check if the hostname set up in the Network Identification page has been
changed. Changing the hostname severs any current CIFS connections to the NSS.