B-8
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
December 2006
Appendix B Hardware Specifications
B.3.2 TCC2P Card Specifications
–
Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate)
–
Interface: 10BaseT LAN (on TCC2 faceplate)
–
Interface: 10BaseT LAN (through the backplane)
•
Synchronization
–
Stratum 3, per Telcordia GR-253-CORE
–
Free running access: Ac/– 4.6 ppm
–
Holdover stability: 3.7 x 10
-7
per day including temperature (< 255 slips in first 24 hours)
–
Reference: External BITS, line, internal
•
Supply voltage monitoring
–
Both supply voltage inputs are monitored.
–
Normal operation: –40.5 to –56.7 V
–
Undervoltage: Major alarm
–
Overvoltage: Major alarm
•
Environmental
–
Operating temperature: –40 to +149 degrees Fahrenheit (–40 to +65 degrees Celsius)
–
Operating humidity: 5 to 95 percent, noncondensing
–
Power consumption: 26.00 W, 0.54 A at –48 V, 88.8 BTU/hr
•
Dimensions
–
Height: 12.650 in. (321.3 mm)
–
Width: 0.716 in. (18.2 mm)
–
Depth: 9.000 in. (228.6 mm)
–
Depth with backplane connector: 235 mm (9.250 in.)
–
Weight not including clam shell: 0.7 kg (1.5 lb)
B.3.2 TCC2P Card Specifications
The TCC2P card has the following specifications:
•
CTC software
–
Interface: EIA/TIA-232 (local craft access, on TCC2P faceplate)
–
Interface: 10BaseT LAN (on TCC2P faceplate)
–
Interface: 10BaseT LAN (through the backplane)
•
Synchronization
–
Stratum 3, per Telcordia GR-253-CORE
–
Free running access: Ac/– 4.6 ppm
–
Holdover stability: 3.7 * 10 exp – 7 per day including temperature (< 255 slips in first 24 hours)
–
Reference: External BITS, line, internal
•
Supply voltage monitoring
–
Both supply voltage inputs are monitored.
Summary of Contents for ONS 15454 DWDM