B-10
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
December 2006
Appendix B Hardware Specifications
B.3.4 AEP Specifications (ANSI only)
–
Orderwire party line
–
Dual tone, multifrequency (DTMF) signaling
•
User data channel (UDC)
–
Bit rate: 64 kbps, codirectional
–
ITU-T G.703
–
Input/output impedance: 120 ohm
–
Termination: RJ-11 connectors
•
Data communications channel (DCC)
–
Bit rate: 576 kbps
–
EIA/TIA-485/V11
–
Input/output impedance: 120 ohm
–
Termination: RJ-45 connectors
•
ACC connection for additional alarm interfaces
–
Connection to AEP
•
Power monitoring alarming states:
–
Power failure (0 to –38 VDC)
–
Undervoltage (–38 to –40.5 VDC)
–
Overvoltage (beyond –56.7 VDC)
•
Environmental
–
Operating temperature: –40 to 149 degrees Fahrenheit (–40 to +65 degrees Celsius)
–
Operating humidity: 5 to 95 percent, noncondensing
–
Power consumption (including AEP, if used): 8.00 W, 0.17 A, 27.3 BTU/hr
•
Dimensions
–
Height: 12.650 in. (321.3 mm)
–
Width: 0.716 in. (18.2 mm)
–
Depth: 9.000 in. (228.6 mm)
–
Weight: 1.8 lb (0.82 kg)
B.3.4 AEP Specifications (ANSI only)
The AEP has the following specifications:
•
Alarm inputs
–
Number of inputs: 32
–
Optocoupler isolated
–
Label customer provisionable
–
Severity customer provisionable
–
Common 32 V output for all alarm inputs
–
Each input limited to 2 mA