B-22
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
December 2006
Appendix B Hardware Specifications
B.4.11 AD-2C-xx.x Card Specifications
AD-1C-xx.x optical input and output power varies with amplifier output levels and the class of
transponder interfaces used. See
for this
information.
The AD-1C-xx.x card has the following additional specifications:
•
Environmental
–
Operating temperature:
C-Temp: –5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–
Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH
•
Dimensions
–
Height: 12.650 in. (321.3 mm)
–
Width: 0.92 in. (23.4 mm)
–
Depth: 9.0 in. (228.6 mm)
B.4.11 AD-2C-xx.x Card Specifications
lists the AD-2C-xx.x optical specifications.
Table B-8
AD-1C-xx.x Card Optical Specifications
Parameter
Note
Condition
Min
Max
Unit
Trx filter shape
(–0.5 dB bandwidth)
TrxBW
2
All SOP and within whole
operating temperature range
COM Rx—xx.xx Tx
xx.xx Rx—COM Tx
+/–180
—
pm
Rfx filter shape
(–0.5 dB bandwidth)
RfxBW
2
All SOP and within whole
operating temperature range
COM Rx—Exp Tx
Exp Rx—COM Tx
+/–180
—
pm
Insertion loss
(drop section)
All SOP and within whole
operating temperature range
(two connectors included)
COM Rx—xx.xx Tx
—
2.0
dB
Insertion loss
(express section)
VOA at minimum attenuation;
all SOP and within whole
operating temperature range
(two connectors included)
COM Rx—Exp Tx
Exp Rx—COM Tx
—
2.4 or
1.2
dB
Insertion loss
(add section)
VOA at minimum attenuation;
all SOP and within whole
operating temperature range
(two connectors included)
xx.xx Rx—COM Tx
—
2.6
dB
VOA dynamic range
—
—
30
—
dB
Maximum optical
input power
—
—
300
—
mW
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...