1-28
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
August 2005
Chapter 1 Install the Shelf and Common Control Cards
NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only)
Step 4
Store the panel for later use. Attach the backplane cover(s) whenever electrical interface assemblies
(EIAs) are not installed.
Step 5
Return to your originating procedure (NTP).
NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only)
Caution
Always use the supplied ESD wristband when working with a powered ONS 15454 ETSI. Plug the
wristband cable into the ESD jack located on the lower-right outside edge of the shelf assembly.
Warning
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,
keep hands and fingers out of the power supply bays and backplane areas.
Statement 166
Note
The ONS 15454 ETSI EFCA has 12 FMEC slots numbered sequentially from left to right beginning with
Slot 18. Slots 18 to 22 and 25 to 29 provide electrical connections for the corresponding slots, so they
are unnecessary in dense wave division multiplexing (DWDM) applications.
Step 1
Ensure you are installing the FMECs in the correct slot:
•
FMEC Slot 23 supports the MIC-A/P.
The MIC-A/P card provides connection for the BATTERY B input, one of the two possible
redundant power supply inputs. It also provides connection for eight alarm outputs (coming from
the TCC2/TCC2P card), sixteen alarm inputs, and four configurable alarm inputs/outputs.
•
FMEC Slot 24 supports the MIC-C/T/P.
The MIC-C/T/P card provides connection for the BATTERY A input, one of the two possible
redundant power supply inputs. It also provides connection for system management serial port,
system management LAN port, and system timing inputs and outputs.
Purpose
This procedure installs the MIC-A/P and the MIC-T/C/P, which are a type
of FMEC installed in the EFCA. The EFCA is located at the top of the
ONS 15454 ETSI shelf. It provides connection for installing power,
external alarms, timing input and output, and craft interface terminals.This
procedure applies to the ETSI shelf only.
Tools/Equipment
#2 Phillips screwdriver
Medium slot-head screwdriver
Small slot-head screwdriver
FMEC cards (the MIC-A/P and MIC-T/C/P)
Prerequisite Procedures
NTP-G4 Open and Remove the FMEC Cover (ETSI Only), page 1-23
Required/As Needed
Required
Onsite/Remote
Onsite
Security Level
None
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...