D-97
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
August 2005
Appendix D Network Element Defaults
D.3.1 ETSI Card Default Settings
TXPP-MR-2_5G.config.client.ppmSlotAssignment
UNASSIGNE
D
UNASSIGNED, PPM (1 Port)
TXPP-MR-2_5G.config.client.SDBER
1E-7
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
TXPP-MR-2_5G.config.client.SFBER
1E-4
1E-3, 1E-4, 1E-5
TXPP-MR-2_5G.config.client.TerminationMode
Transparent
•
Transparent, Regeneration
Section, Multiplex Section
when ppmPortAssignment
is UNASSIGNED,
STM1_PORT,
STM4_PORT,
STM16_PORT
•
Transparent when
ppmPortAssignment is
STM1_PORT,
STM4_PORT,
STM16_PORT,
ONE_GE_PORT,
ESCON_PORT,
DV6000_PORT,
SDI_D1_VIDEO_PORT,
HDTV_PORT,
PASS_THRU_PORT,
ETR_CLO_PORT, ISC
compat, FC1G_PORT,
FC2G_PORT,
FICON1G_PORT,
FICON2G_PORT, ISC peer
TXPP-MR-2_5G.config.trunk.AINSSoakTime
08:00
(hours:mins)
00:00, 00:15, 00:30 .. 48:00
TXPP-MR-2_5G.config.trunk.AlsMode
Disabled
Disabled, Auto Restart, Manual
Restart, Manual Restart for Test
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseDuration
40.0 (seconds)
•
2.0, 2.1, 2.2 .. 100.0 when
AlsMode is Disabled, Auto
Restart, Manual Restart
•
80.0, 80.1, 80.2 .. 100.0
when AlsMode is Manual
Restart for Test
TXPP-MR-2_5G.config.trunk.AlsRecoveryPulseInterval
100 (seconds)
60–300
TXPP-MR-2_5G.config.trunk.SDBER
1E-7
1E-5, 1E-6, 1E-7, 1E-8, 1E-9
TXPP-MR-2_5G.config.trunk.SFBER
1E-4
1E-3, 1E-4, 1E-5
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighLaserBias
90.0 (%)
0.0, 0.1, 0.2 .. 100.0
TXPP-MR-2_5G.opticalthresholds.client.alarm.HighRxPower
3.0 (dBm)
LowRxPower, LowR
0.1, LowR 0.2 .. 30.0
Table D-20
TXPP-MR-2.5G Card Default Settings (ETSI) (continued)
Default Name
Default Value
Default Domain