5-19
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 5 Provision Transponder and Muxponder Cards
DLP-G219 Change the TXP_MR_10G or TXP_MR_10E Card Line Thresholds for SONET or SDH Payloads
DLP-G219 Change the TXP_MR_10G or TXP_MR_10E Card Line Thresholds for
SONET or SDH Payloads
Step 1
In node view, double-click the TXP_MR_10G or TXP_MR_10E card where you want to change the line
threshold settings.
Step 2
Click the
Provisioning > Line Thresholds > SONET Thresholds
tabs.
Step 3
Modify any of the settings described in
Note
You must modify Near End and Far End independently; 15 Min and 1 Day independently; and
Line and Section independently. To do so, choose the appropriate radio button and click
Refresh
.
Purpose
This task changes the line threshold settings for TXP_MR_10G and
TXP_MR_10E transponder cards carrying SONET or SDH payloads,
including the physical 10G Ethernet WAN payload.
Tools/Equipment
None
Prerequisite Procedures
DLP-G46 Log into CTC, page 2-25
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Table 5-6
TXP_MR_10G and TXP_MR_10E Transponder Card Line Threshold Settings
Parameter Description
Options – ONS 15454
Options – ONS 15454 SDH
Port (Display
only)
Port number
•
1-1 (OC192)
•
2 (Trunk)
•
1-1 (STM64)
•
2 (Trunk)
CV
Coding
violations
Numeric. Threshold display options include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Line or Section (near end only)
Choose an option in each category and click
Refresh
.
Numeric. Threshold display options include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh
.
ES
Errored
seconds
Numeric. Threshold display options include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Line or Section (near end only)
Choose an option in each category and click
Refresh
.
Numeric. Threshold display options include:
•
Direction—Near End or Far End
•
Interval—15 Min (minutes) or 1 day
•
Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh
.