15-12
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
September 2005
Chapter 15 Shelf Hardware Reference
15.4.1 FlexLayer Modules
shows the physical appearance of the ONS 15454 two-channel add/drop FlexLayer module.
Figure 15-7
ONS 15454 Two-Channel Optical Add/Drop FlexLayer Module
Labels are provided to show how the module ports are mapped. It is the end user’s responsibility to label
the module for its intended use (drop or add component).
shows how the connectors are mapped and labeled on the front panel when the component
is used as a drop component. The COM-RX is mapped to Port 1, the COM-TX is mapped to Port 12, and
the two dropped channel TX ports are mapped to Ports 9 and 10. The two-percent tap MON port is
mapped to Port 6. Port 7 is not active.
Figure 15-8
Two-Channel Drop Component Connector Mapping and Labeling
shows how the connectors are mapped and labeled in the front panel when the component
is used as an add component. The COM-TX is mapped to Port 1, the COM-RX is mapped to Port 12, and
the added channels are mapped to the two RX Ports 9 and 10. The two-percent tap MON port is mapped
to Port 7. Port 6 is not active.
Front Panel
90948
1
6
9
10
2 Channel Drop Module 15216-FLB-2-XX.X
MON
15XX.XX
TX
15XX.XX
TX
COM-RX
2% TAP
12
COM-TX
90949