16-45
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
April 2006
Chapter 16 Card Reference
16.6 Multiplexer and Demultiplexer Cards
16.5.3.2 OPT-BST-E Amplifier Card-Level Indicators
The OPT-BST-E amplifier has three card-level LED indicators, described in
16.5.3.3 OPT-BST-E Port-Level Indicators
You can find the status of the card ports using the LCD screen on the ONS 15454 fan-tray assembly. Use
the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms
for a given port or slot. The OPT-BST-E amplifier has eight optical ports located on the faceplate.
MON RX is the output monitor port (receive section). MON TX is the output monitor port. COM RX is
the input signal port. LINE TX is the output signal port. LINE RX is the input signal port (receive
section). COM TX is the output signal port (receive section). OSC RX is the OSC add input port.
OSC TX is the OSC drop output port.
16.6 Multiplexer and Demultiplexer Cards
This section describes the multiplexer and demultiplexer cards.
16.6.1 32MUX-O Card
The 32-Channel Multiplexer (32MUX-O) card multiplexes 32 100-GHz-spaced channels identified in
the channel plan. The 32MUX-O card takes up two slots in an ONS 15454 and can be installed in
Slots 1 to 5 and 12 to 16.
The 32MUX-O features include:
•
Arrayed waveguide grating (AWG) device that enables full multiplexing functions for the channels.
P3
Output COM
LINE RX
P4
Output OSC
Table 16-24
OPT-BST-E Port Calibration (continued)
Photodiode
CTC Type Name
Calibrated to Port
Table 16-25
OPT-BST-E Card-Level Indicators
Card-Level Indicators
Description
Red FAIL LED
The red FAIL LED indicates that the card’s processor is not ready or that
there is an internal hardware failure. Replace the card if the red FAIL LED
persists.
Green ACT LED
The green ACT LED indicates that the OPT-BST-E is carrying traffic or is
traffic-ready.
Amber SF LED
The amber SF LED indicates a signal failure or condition such as LOS on
one or more of the card’s ports. The amber SF LED also illuminates when
the transmit and receive fibers are incorrectly connected. When the fibers are
properly connected, the light turns off.
Summary of Contents for ONS 15454 DWDM
Page 38: ...Figures xxxviii Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 54: ...Procedures liv Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 ...
Page 64: ... 64 Cisco ONS 15454 DWDM Installation and Operations Guide R6 0 August 2005 Chapter ...