Table 21: Alarm Input Pin Assignments
Signal Name
AMP Champ Pin
Signal Name
AMP Champ Pin
GND
27
ALARM_IN_1–
1
ALARM_IN_2–
28
GND
2
ALARM_IN_4–
29
ALARM_IN_3–
3
GND
30
ALARM_IN_5–
4
ALARM_IN_6–
31
GND
5
ALARM_IN_8–
32
ALARM_IN_7–
6
GND
33
ALARM_IN_9–
7
ALARM_IN_10–
34
GND
8
ALARM_IN_12–
35
ALARM_IN_11–
9
GND
36
ALARM_IN_13–
10
ALARM_IN_14–
37
GND
11
ALARM_IN_16–
38
ALARM_IN_15–
12
GND
39
ALARM_IN_17–
13
ALARM_IN_18–
40
GND
14
ALARM_IN_20–
41
ALARM_IN_19–
15
GND
42
ALARM_IN_21–
16
ALARM_IN_22–
43
GND
17
ALARM_IN_24–
44
ALARM_IN_23–
18
GND
45
ALARM_IN_25–
19
ALARM_IN_26–
46
GND
20
ALARM_IN_28–
47
ALARM_IN_27–
21
GND
48
ALARM_IN_29–
22
ALARM_IN_30–
49
GND
23
—
50
ALARM_IN_31–
24
GND1
51
AL
25
GND2
52
ALARM_IN_0-
26
The following table lists the alarm output (external control) pin assignments.
Cisco ONS 15454 Hardware Installation Guide
114
Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
NTP-G11 Install an External Wire-Wrap Panel on the AEP (ANSI Only)
Summary of Contents for ONS 15454
Page 2: ... 2019 Cisco Systems Inc All rights reserved ...
Page 16: ...Cisco ONS 15454 Hardware Installation Guide xvi Contents ...
Page 28: ...Cisco ONS 15454 Hardware Installation Guide xxviii Preface Preface ...
Page 36: ...Cisco ONS 15454 Hardware Installation Guide 6 Overview Cisco ONS 15454 M6 Shelf ...
Page 510: ...Cisco ONS 15454 Hardware Installation Guide 480 Hardware Specifications Dimensions ...