Figure 65: Connecting the EAP to the Node Controller and Subtending Shelf
Step 2
To connect a subtending shelf to the EAP, complete the following (see
Figure 65: Connecting the EAP to the
Node Controller and Subtending Shelf, on page 140
a) Using a cross-over (CAT-5) LAN cable, plug one connector into the front panel of the subtending shelf
TCC2/TCC2P/TCC3 card in Slot 7 and plug the other end into the SSC1 port on the left EAP.
b) Using a cross-over (CAT-5) LAN cable, plug one connector into the front panel of the subtending shelf
TCC2/TCC2P/TCC3 card in Slot 11 and plug the other end into the SSC1 port on the right EAP.
c) Repeat Steps a and b for each subtending shelf in the multishelf configuration. Use the same SSC port
number (2 through 8) on the left and right EAP for each subtending shelf.
Cisco ONS 15454 Hardware Installation Guide
140
Installing the ONS 15454 M12 (ANSI and ETSI) Shelf
NTP-G301 Connect the ONS 15454 Multishelf Node and Subtending Shelves to an MS-ISC-100T Card
Summary of Contents for ONS 15454
Page 2: ... 2019 Cisco Systems Inc All rights reserved ...
Page 16: ...Cisco ONS 15454 Hardware Installation Guide xvi Contents ...
Page 28: ...Cisco ONS 15454 Hardware Installation Guide xxviii Preface Preface ...
Page 36: ...Cisco ONS 15454 Hardware Installation Guide 6 Overview Cisco ONS 15454 M6 Shelf ...
Page 510: ...Cisco ONS 15454 Hardware Installation Guide 480 Hardware Specifications Dimensions ...