DLP-G765 Install Air Plenum for ONS 15454 M2 Shelf in ETSI Configuration
This task installs the air plenum for the ONS 15454 M2 shelf in the ETSI configuration.
Purpose
• #2 Phillips Dynamometric screwdriver
• Medium slot-head screwdriver
• Small slot-head screwdriver
• Screws: M6.0 x 20 pan-head Phillips screws (4)
• Wing head screws (4)
• Adapter plates
• One air plenum kit (horizontal and vertical air plenum)
Tools/Equipment
As needed
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Procedure
Step 1
Install the ETSI adapter plates on the horizontal air plenum.
Step 2
Align the screws to fix the adapter plates to the horizontal air plenum. Insert the screws and tighten them to
a torque value of 11.5 in-lb (1.3 N-m) as shown in the following figure.
Cisco ONS 15454 Hardware Installation Guide
191
Installing the ONS 15454 M2 Shelf
DLP-G765 Install Air Plenum for ONS 15454 M2 Shelf in ETSI Configuration
Summary of Contents for ONS 15454