• #2 Phillips Dynamometric screwdriver
• Medium slot-head screwdriver
• Small slot-head screwdriver
• Screws: M6.0 x 20 pan-head Phillips screws (8)
• Wing head screws (8)
• Adapter plates
• One air plenum kit (horizontal and vertical air plenum)
Tools/Equipment
As needed
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Procedure
Step 1
Install the ETSI adapter plates on the horizontal air plenums.
Step 2
Align the screws to fix the adapter plates to the shelf. Insert the screws and tighten them to a torque value of
11.5 in-lb (1.3 N-m).
Figure 192: Installing the adapter plates on the horizontal air plenum
Step 3
Place the horizontal plenum below the chassis slot in the ETSI cabinet.
Step 4
Install the wing head screws provided with the kit, and tighten to a torque value of 11.5 in-lb (1.3 N-m).
Cisco ONS 15454 Hardware Installation Guide
290
Installing the ONS 15454 M6 Shelf
DLP-G769 Install Air Plenum for ONS 15454 M6 Shelf in ETSI Configuration