None
Prerequisite Procedures
Required
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Procedure
Step 1
Remove the dust plug from the fiber adapter.
Step 2
Insert a CLETOP stick swab (14100400) into the adapter opening and rotate the swab.
Step 3
Place dust plugs on the fiber adapters when not in use.
Step 4
Return to your originating procedure (NTP).
NTP-G40 Replace the Front Door
This procedure replaces the front door and door ground strap after installing cards
and fiber-optic cables.
Purpose
#2 Phillips screwdriver
Medium slot-head screwdriver
Small slot-head screwdriver
Tools/Equipment
NTP-G259 Open and Remove the Standard Door of the ONS 15454 M6 Shelf ,
on page 327
Prerequisite Procedures
Required
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Be careful not to crimp any fiber cables that are connected to the MXP/TXP cards or DWDM cards. Some
might not have the fiber boot attached.
Note
Procedure
Step 1
Insert the front door into the hinges on the shelf assembly.
Step 2
(ANSI only) Attach one end of the ground strap terminal lug (72-3622-01) to the male stud on the inside of
the door. Attach and tighten the #6 Kepnut (49-0600-01) using the open-end wrench.
Cisco ONS 15454 Hardware Installation Guide
448
Maintaining the ONS 15454 M12 (ANSI and ETSI), ONS 15454 M2 and ONS 15454 M6 Shelf
NTP-G40 Replace the Front Door
Summary of Contents for ONS 15454
Page 2: ... 2019 Cisco Systems Inc All rights reserved ...
Page 16: ...Cisco ONS 15454 Hardware Installation Guide xvi Contents ...
Page 28: ...Cisco ONS 15454 Hardware Installation Guide xxviii Preface Preface ...
Page 36: ...Cisco ONS 15454 Hardware Installation Guide 6 Overview Cisco ONS 15454 M6 Shelf ...
Page 510: ...Cisco ONS 15454 Hardware Installation Guide 480 Hardware Specifications Dimensions ...