Figure 12: Reversing the Mounting Brackets (23-inch [584.2-mm] Position to 19-inch [482.6-mm] Position
Step 7
Return to your originating procedure (NTP).
DLP-G4 Install the External Brackets and Air Filter (ANSI Only)
This task installs the external brackets and air filter on the bottom of the shelf
rather than below the fan-tray assembly. Installing the external brackets and air
filter on the bottom of the shelf enables access to the air filter without removing
the fan-tray assembly. This task applies to the ONS 15454 ANSI shelf only.
Purpose
#2 Phillips Dynamometric screwdriver
Medium slot-head screwdriver
Small slot-head screwdriver
Tools/Equipment
DLP-G3 Reverse the Mounting Bracket to Fit a 19-inch (482.6-mm) Rack (ANSI
Only), on page 33
, if applicable
Prerequisite Procedures
As needed
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
To install the air filter inside the air ramp unit (15454E-AIR-RAMP or 15454-AIR-RAMP), use the ETSI
version of the air filter (15454-FTF2 or 15454E-FTF4).