Figure 200: DC Power Module Installation—Rear Side of the ONS 15454 M6 Shelf
Step 2
Loosen the screw and move it to the right position (towards the DC silk-screen text).
Step 3
Tighten the screw again to a torque value of 4 in-lb (0.45 N-m).
Step 4
Return to your originating procedure (NTP).
DLP-G560 Mounting the Reversible Brackets on the ONS 15454 M6 Shelf for
ANSI Rack Configuration
This task installs the reversible mounting brackets on the ONS 15454 M6 shelf
for ANSI rack configuration.
Purpose
• #2 Phillips Dynamometric screwdriver
• Medium slot-head screwdriver
• Small slot-head screwdriver
Tools/Equipment
NTP-G305 Unpack and Inspect the ONS 15454, ONS 15454 M2, and ONS 15454
M6 Shelves, on page 20
Prerequisite Procedures
As needed
Required/As Needed
Onsite
Onsite/Remote
None
Security Level
Use only the fastening hardware provided with the ONS 15454 M6 to prevent loosening, deterioration, and
electromechanical corrosion of the hardware and joined material.
Caution
Cisco ONS 15454 Hardware Installation Guide
299
Installing the ONS 15454 M6 Shelf
DLP-G560 Mounting the Reversible Brackets on the ONS 15454 M6 Shelf for ANSI Rack Configuration
Summary of Contents for ONS 15454