4-10
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Chapter 4 Command Reference
gainmean
gainmean
To display the configured signal gain and alarm mean level, use the gainmean command.
gainmean
Syntax Description
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Usage Guidelines
The value for configured Cisco ONS 15501 signal gain and alarm mean level is displayed in dB.
Examples
The following example shows how to display the configured signal gain and alarm mean level.
edfa > gainmean
17.50 (dB)
Related Commands
This command has no other arguments or keywords.
Release
Modification
EDFA 1.0
This command was introduced.
Command
Description
Displays the measured optical signal gain.
Displays the gain alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer’s default settings.
Sets the signal gain and alarm mean level.
Sets the gain alarm trigger level.