4-33
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Chapter 4 Command Reference
resetmeantrig
resetmeantrig
To reset the alarm mean and trigger levels for signal gain, optical input power, output signal power, and
internal case temperature to the manufacturer’s default settings, use the resetmeantrig command.
resetmeantrig
Syntax Description
Defaults
None
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Usage Guidelines
The manufacturer’s default setting for signal gain and alarm mean level is 17.50 dB.
The manufacturer’s default setting for gain alarm trigger level is 1.00 dB.
The manufacturer’s default setting for optical input alarm mean level is -29.00 dBm.
The manufacturer’s default setting for optical input alarm trigger level is 1.00 dBm.
The manufacturer’s default setting for output signal alarm mean level is 2.00 dBm.
The manufacturer’s default setting for output signal alarm trigger level is 20.00 dBm.
The manufacturer’s default setting for internal case temperature alarm mean level is 30°C.
The manufacturer’s default setting for internal case temperature alarm trigger level is 30°C.
Related Commands
This command has no other arguments or keywords.
Release
Modification
EDFA 1.0
This command was introduced.
Command
Description
Displays the configured signal gain and alarm mean level.
Displays the gain alarm trigger level.
Displays the optical input alarm mean level.
Displays the optical input alarm trigger level.
Displays the output signal alarm mean level.
Displays the output signal alarm trigger level.
Sets the signal gain and alarm mean level.
Sets the gain alarm trigger level.