4-37
Cisco ONS 15501 User Guide
78-14134-01, Release 1.0
Chapter 4 Command Reference
setgaintrig
setgaintrig
To modify the signal gain alarm trigger level, use the setgaintrig command.
setgaintrig trigger
Syntax Description
Defaults
1.00 dB
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Usage Guidelines
The signal gain alarm trigger level is measured in dB. The system accepts a minimum value of 1 dB and
a maximum value of 17.5 dB. If a value entered falls outside of this acceptable range, the command will
be ignored and have no effect.
Examples
The following example shows how to modify the gain alarm trigger level.
edfa > setgaintrig 2.00
Related Commands
trigger
Specifies the desired signal gain and alarm trigger.
Release
Modification
EDFA 1.0
This command was introduced.
Command
Description
Displays the measured optical signal gain.
Displays the configured signal gain and alarm mean level.
Displays the gain alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer’s default settings.
Sets the signal gain and alarm mean level.