Configuring Redundancy
78-4015908-01 Rev F
37
Example 1: Single Chassis Configuration
This example shows the control parameter values needed to define the Master-Slave
relationship between two receiver modules installed in slots 1 and 12 of chassis 23.
Prisma XD Chassis
ICIM bus terminator
(PN 4013014) required only if
ICIM is not installed. Terminator
is plugged into the male “ICIM”
DB-9 on the rear of the chassis.
HD-RxR in slot 1
(Master)
HD-RxR in slot 12
(Slave)
Control
Mode
Mode1
Mode2
Alarm1
Alarm2
Red1Chas
Red1Slot
Red1Sub
Red2Chas
Red2Slot
Red2Sub
Slot 1 Settings
Independent
Master
Master
Off
Off
23
12
1
23
12
2
Slot 12 Settings
Independent
Slave
Slave
Off
Off
23
1
1
23
1
2
Chassis ID = 23
Note:
Because each receiver channel is individually configurable, pairs of control
parameters (Mode 1 and Mode2, Alarm1 and Alarm2, etc.) are needed to define the
settings for each module. All controls are described in
Module Parameter
Descriptions
(on page 107).