Tools and Torque Specifications
4013399 Rev C
17
Part
Torque Specification
KS-connector
Tighten according to manufacturer‟s
recommended torque specification, typically 15
ft-lb to 25 ft-lb (20.3 Nm to 33.9 Nm), but not to
exceed 60 ft-lb (81.3 Nm)
Port end plug
50 in-lb to 60 in-lb (5.6 Nm to 6.8 Nm)
Seizure screw
15 in-lb to 20 in-lb (1.7 Nm to 2.3 Nm)
Faceplate bolt
50 in-lb to 60 in-lb (5.6 Nm to 6.8 Nm)
F-connector (drop cable)
RG–6 or RG–59
Tighten to manufacturer‟s recommended
torque specification
Installations involving a twisted-pair PDU also require tightening the PDU cover
screw to 50 to 60 in-lb (5.6 to 6.8 Nm).
Torque Sequence
The following diagrams show the proper torque sequence for closing the housing.
2/4-Way Standard Tap
8-Way Full Profile Tap