Chapter 2 Installing the Tap
32
4013399 Rev C
Installing the Coax PDU
Follow these steps to install the Coax PDU.
1
Ensure that the PDU AC power switches are in the “OFF” position. If the PDU is
“ON,” use a flat-bladed screwdriver to turn the switch off. Refer to the
illustration below for location of the “ON” and “OFF” positions of the AC power
switches in the 8-way PDU.
Important:
It is important to perform this step now in order to prevent
unwanted AC power transmission on a subscriber drop during installation.
2
Using a 3/8 in. wrench, remove the faceplate from the existing tap by loosening
the 3/8-in. faceplate bolts. See
Removing the Faceplate
(on page 20).
3
Remove the longer faceplate bolts attached to the plastic protective cover of the
PDU. Replace the shorter bolts removed from the faceplate with the existing
faceplate bolts.
4
Remove the plastic protective cover from the Multimedia Tap faceplate.
CAUTION:
Be careful not to disturb or damage electrical components.
Summary of Contents for Surge-Gap Multimedia Tap
Page 1: ...4013399 Rev C Surge Gap Multimedia Tap Installation and Operation Guide ...
Page 2: ......
Page 33: ...Preparing for Installation 4013399 Rev C 19 ...
Page 60: ......
Page 62: ...Chapter 3 Customer Support Information 48 4013399 Rev C ...
Page 70: ......
Page 73: ......