7-20
Firepower 7000 and 8000 Series Installation Guide
Chapter 7 Hardware Specifications
Firepower 7000 Series Devices
Firepower 7115, 7125, and AMP7150 Physical and Environmental Parameters
The following table describes the physical attributes and the environmental parameters for the appliance.
Blinking green
AC input is present; volts on standby, the power supply is switched off.
Green
The power supply is plugged in and on.
Table 7-32
Firepower 7115, 7125, and AMP7150 Power Supply LED (continued)
LED
Description
Table 7-33
Firepower 7115, 7125, and AMP7150 Physical and Environmental Parameters
Parameter
Description
Form factor
1U
Dimensions (D x W x H)
21.6 in. x 19.0 in. x 1.73 in. (54.9 cm x 48.3 cm x 4.4 cm)
Weight
maximum installed
29.0 lbs (13.2 kg)
Copper 1000BASE-T
Gigabit copper Ethernet bypass-capable interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Copper 1000BASE-T SFP
Gigabit copper Ethernet non-bypass capable interfaces in a paired configuration
Cable and distance: Cat5E at 50 m
Fiber 1000BASE-SX SFP
Fiber non-bypass capable interfaces with LC connectors
Cable and distance: SX is multimode fiber (850 nm) at 550 m (standard)
656 ft (200 m) for 62.5 µm/125 µm fiber
1640 ft (500 m) for 50 µm/125 µm fiber
Fiber 1000BASE-LX SFP
Fiber non-bypass capable interfaces with LC connectors
Cable and distance: LX is single mode fiber (1310 nm) at 10 km for
9 µm/125 µm fiber (standard)
Power supply
450 W dual redundant (1+1) AC power supplies
Voltage: 100 VAC to 240 VAC nominal (85 VAC to 264 VAC maximum)
Current: 3A maximum for 90 VAC to 132 VAC, per supply
1.5A maximum for 187 VAC to 264 VAC, per supply
Frequency range: 47 Hz to 63 Hz
Operating temperature
41
o
F to 104
o
F (5
o
C to 40
o
C)
Non-operating temperature
-29
o
F to 158
o
F (-20
o
C to 70
o
C)
Operating humidity
5% to 85% non-condensing
Non-operating humidity
5% to 90%, non-condensing with a maximum wet bulb of 82
o
F (28
o
C) at temperatures from
77
o
F to 95
o
F (25
o
C to 35
o
C)
Store the unit below 95% non-condensing relative humidity. Acclimate below maximum
operating humidity at least 48 hours before placing the unit in service.
Altitude
0ft (sea level) to 5905 ft (0 m to 1800 m)
Cooling requirements
900 BTU/hour
You must provide sufficient cooling to maintain the appliance within its required operating
temperature range. Failure to do this may cause a malfunction or damage to the appliance.