3-46
Cisco UCS C220 M4 Server Installation and Service Guide
OL-32473-01
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Figure 3-23
SCPM Bracket Location
Replacing a Software RAID 5 Key Module
The server has a two-pin header on the motherboard for a RAID 5 key module. This module upgrades
the embedded software RAID controller options to add RAID 5 support (see
Step 1
Prepare the server for component installation:
a.
Power off the server as described in
Shutting Down and Powering Off the Server, page 3-8
.
b.
Slide the server out the front of the rack far enough so that you can remove the top cover. You might
have to detach cables from the rear panel to provide clearance.
Caution
If you cannot safely view and access the component, remove the server from the rack.
c.
Remove the top cover as described in
Removing and Replacing the Server Top Cover, page 3-9
Step 2
Remove any existing software RAID 5 key module:
a.
Locate the module on the motherboard (see
).
b.
Hold the retention clips on the header open while you grasp the RAID key board and pull straight
up (see
).
1
SCPM mounting bracket between fans 3 and 4
3
Retainer bar securing clip
2
Retainer bar
353097
FAN 4
FAN 3
1
3
2