3-9
Cisco UCS C220 M4 Server Installation and Service Guide
OL-32473-01
Chapter 3 Maintaining the Server
Preparing for Server Component Installation
Removing and Replacing the Server Top Cover
Step 1
Remove the top cover (see
).
a.
If the cover latch is locked, use a screwdriver to turn the lock 90-degrees counterclockwise to unlock
it. See
b.
Lift on the end of the latch that has the green finger grip. The cover is pushed back to the open
position as you lift the latch.
c.
Lift the top cover straight up from the server and set it aside.
Step 2
Replace the top cover:
Note
The latch must be in the fully open position when you set the cover back in place, which allows
the opening in the latch to sit over a peg that is on the fan tray.
a.
With the latch in the fully open position, place the cover on top of the server about one-half inch
(1.27 cm) behind the lip of the front cover panel. The opening in the latch should fit over the peg
that sticks up from the fan tray.
b.
Press the cover latch down to the closed position. The cover is pushed forward to the closed position
as you push down the latch.
c.
If desired, lock the latch by using a screwdriver to turn the lock 90-degrees clockwise.
Figure 3-4
Removing the Top Cover
1
Top cover
2
Locking cover latch
353091
1
2