If a rear NVMe switch card is used, it must be installed in PCIe slot 10.
Note
Step 1
Prepare the server for component installation:
a) Shut down and remove power from the server as described in
Shutting Down and Removing Power From the Server,
.
b) Slide the server out the front of the rack far enough so that you can remove the top cover. You might have to detach
cables from the rear panel to provide clearance.
If you cannot safely view and access the component, remove the server from the rack.
Caution
c) Remove the top cover from the server as described in
Removing the Server Top Cover, on page 9
.
Step 2
Remove any existing rear NVMe switch card from PCIe slot 10:
a) Disconnect the PCIe cable from the existing card.
b) Open the hinged retainer bar that covers the top of PCIe slot 10. See
Replacing a PCIe Card, on page 64
Use your fingertips to pull back on the wire locking-latches at each end of the retainer bar, and then hinge the bar
open to expose the tops of the PCIe slots.
c) Open the card's blue ejector lever to unseat it from PCIe slot 10.
d) Pull both ends of the card vertically to disengage the card from the socket, and then set it aside.
Step 3
Install a new rear NVMe switch card:
a) Carefully align the card edge with the socket of PCIe slot 10.
b) Push on both corners of the card to seat its connector in the socket.
c) Fully close the blue ejector lever on the card to lock the card into the socket.
d) Connect the PCIe cable (CBL-AUX-NVME-M5) from the internal drive module backplane to the new switch card.
e) Close the hinged retainer bar over the top of the PCIe slots.
Use your fingertips to pull back on the wire locking-latches at each end of the retainer bar, and then hinge it closed
to lock in the tops of the PCIe slots. Push the wire locking-latching back to the forward, locked position.
Step 4
Replace the top cover to the server.
Step 5
Reconnect power cords to all power supplies and then allow the server to boot to standby power mode (indicated when
the front panel Power button LED lights amber).
Step 6
Fully power on the server by pressing the Power button.
Maintaining the Server
52
Maintaining the Server
Replacing a Rear NVMe Switch Card