2-9
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
Chapter 2 Installing the System
Installing the System in a Rack
Figure 2-4
Attaching Rail Assembly to the Rack Post
Step 6
(
Recommended) Secure the chassis in the rack more permanently by using the two screws provided with
the slide rails. For example, you can install these screws if you plan to move the rack with systems
installed.
With the chassis fully pushed into the slide rails, open a hinged slam-latch lever on the front of the
system and insert the screw through the hole that is under the lever. The screw threads into the static part
of the rail on the rack post and prevents the chassis from being pulled out. Repeat for the opposite slam
latch.
Caution
When you pull the chassis outward from the rack, it stops at internal locking stops. Do not depress the
release clips on the inner rails (see
) unless you intend to slide the chassis back into the rack
or to fully remove the chassis from the rack. Depressing the release clips on the inner rails allows the
chassis to slide all the way out of the intermediate rails and could result in injury or equipment damage.
It is recommended that when you test pulling the chassis out from the rack for the first time that you
place the mechanical lift under the chassis to avoid an accidental drop.
1
Intermediate rail pulled out from outer rail
3
Inner rail release clip
2
Inner rail mounted on chassis
353443
3
2
1