Environmental Specifications
Table 7: Environmental Specifications for the Chassis
Specification
Description
50 to 95°F (10 to 35°C)
(As altitude increases, maximum temperature
decreases by 1°C per 300m.)
For general information, see the
Computing System Site Planning Guide: Data Center
Power and Cooling
Temperature, operating within altitude: 0 to 10,000
feet (0 to 3,000 meters)
–40 to 149°F (–40 to 65°C)
Temperature, non-operating within altitude: 0 to
40,000 feet (0 to 12,000 meters)
Operating: 10-90%, 28°C max. wet bulb
Nonoperating: 5-93%, 38°C max wet bulb
Humidity (RH), noncondensing
Operating – 0 to 10000 feet (0 to 3000 meters) Above
10,000 feet, maximum temperature decreases by 1°C
per 1000 feet (~300 meters) above 10,000 feet
Nonoperating – 40,000 ft (12,000 m)
Altitude
83 dBA—at normal operating temperature.
Sound Pressure Level
Environmental Conditions and Power Requirement Specifications for Twinax
SFP+ Transceivers
Table 8: Environmental Conditions and Power Requirement for the SFP+ Transceiver
Unit
Max.
Min.
Symbol
Parameter
°C
85
–40
TS
Storage temperature
°C
50
0
TC
Case temperature
V
3.5
3.1
VCCT,R
Module supply
voltage
Cisco UCS X9508 Server Chassis Installation Guide
110
Technical Specifications
Environmental Specifications
Summary of Contents for UCS X9508
Page 6: ...Cisco UCS X9508 Server Chassis Installation Guide vi Contents ...
Page 26: ...Cisco UCS X9508 Server Chassis Installation Guide 18 Overview Interpreting LEDs ...
Page 31: ...Cisco UCS X9508 Server Chassis Installation Guide 23 Installation Handling the Chassis ...
Page 64: ...Cisco UCS X9508 Server Chassis Installation Guide 56 Installation Repacking the Chassis ...
Page 124: ...Cisco UCS X9508 Server Chassis Installation Guide 116 Technical Specifications Switzerland ...