C H A P T E R
3-1
Cisco VG350 Voice Gateway Hardware Installation Guide
OL-25970-01
3
Planning Your Installation
Before you install your Cisco VG350 Voice Gateway, consider the information in this chapter:
•
Location and Mounting Requirements, page 3-1
•
Distance Limitations for Interface Cables, page 3-4
•
Interference Considerations, page 3-5
Location and Mounting Requirements
The three mounting possibilities for your Cisco VG350 Voice Gateway are as follows:
•
Rack-mount
•
Wall-mount
•
Bench-top
The mounting location must provide the following:
•
Access to the chassis
•
Access to a suitable power source
•
Access to an appropriate earth ground
•
Allowance for adequate heat dissipation and airflow around the chassis
Temperature Control and Ventilation
The installation location (room, closet, or cabinet) for the Cisco VG350 Voice Gateway should always
be well ventilated and provide adequate air circulation to ensure proper cooling. The room temperature
should be maintained between 32 to 122°F (0 to 50°C).
Note
The Cisco VG350 Voice Gateway chassis is designed for back and sides-to-front airflow.