Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note
78-16162-02
Connecting Power to the Fan Tray
Figure 8
Installing the 3000 W Power Supply
Step 4
Tighten the power supply captive installation screw. (See
Figure 7
.)
Step 5
If you have a redundant power supply, install it now following the steps in this section.
Step 6
Proceed to the
“Connecting Power to the Fan Tray” section on page 13
to connect power to the high
speed fan tray.
Connecting Power to the Fan Tray
The high-speed fan tray requires external power, either from the 3000 W AC-input power supply or
from an external DC power source. The fan tray ships with power wires secured at each terminal block.
If you are using the 3000 W AC-input power supply, use the supplied cables to connect the fan tray wires
to the power supply.
If you are using a DC-input power supply, remove the wires from the fan tray and connect directly to a
DC power source.
The following sections describe how to connect power to the fan tray:
•
Installing the Fan Tray Power Cable for AC-Input Systems, page 14
•
Connecting Site Power to the Fan Tray for DC-Input Systems, page 15
FAN
STATUS
105070
SUPERVISOR2
WS-X6K-SUP2-2GE
S
TA
TU
S
SY
ST
EM
C
O
N
SO
LE
P
W
R
M
G
MT
RES
ET
C
O
N
S
O
L
E
C
O
N
S
O
L
E
P
O
R
T
M
O
D
E
P
C
M
C
IA
E
J
E
C
T
P
O
R
T
1
P
O
R
T
2
S
w
itc
h
L
o
a
d
1
0
0
%
1
%
LIN
K
LIN
K
SUPERVISOR2
WS-X6K-SUP2-2GE
ST
AT
U
S
S
Y
ST
EM
C
ON
SOL
E
P
W
R
MG
M
T
RE
SET
C
O
N
S
O
L
E
C
O
N
S
O
L
E
P
O
R
T
M
O
D
E
P
C
M
C
IA
E
J
E
C
T
P
O
R
T
1
P
O
R
T
2
S
w
itc
h
L
o
a
d
1
0
0
%
1
%
LIN
K
LIN
K
S
W
IT
C
H
F
A
B
R
IC
M
D
L
STAT
US
SE
LEC
T
NEX
T
W
S
-C
6
5
0
0
-S
F
M
AC
TIV
E
S
W
IT
C
H
F
A
B
R
IC
M
D
L
ST
AT
US
SE
LE
CT
NE
XT
W
S
-C
6
5
0
0
-S
F
M
AC
TIVE
O
C
1
2
P
O
S
M
M
O
S
M
-4
0
C
1
2
-P
O
S
-M
M
ST
A
TU
S
1
2
3
4
R
E
S
E
T
LINK
1
LINK
2
LINK
3
LIN
K
4
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 1
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 2
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 3
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
R
X
O
C
1
2
P
O
S
M
M
O
S
M
-4
0
C
1
2
-P
O
S
-M
M
S
TAT
US
1
2
3
4
R
E
S
E
T
LIN
K
1
LIN
K
2
LI
NK
3
LIN
K
4
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 1
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 2
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 3
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
R
X
O
C
1
2
P
O
S
M
M
O
S
M
-4
0
C
1
2
-P
O
S
-M
M
S
TAT
U
S
1
2
3
4
R
E
S
E
T
LIN
K
1
LIN
K
2
LIN
K
3
LIN
K
4
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 1
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 2
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
P
O
R
T 3
R
X
C
A
R
R
IE
R
A
LA
R
M
A
C
TIV
E
TX
R
X
TX
R
X
8 PORT OC3 POS MM
OSM-8OC3-POS MM
STATUS
1
1
2
2
3
3
1
2
3
4
4
4
RESET
LINK
CARRIER
ALARM
LINK
LINK
LINK
LINK
5
6
7
8
8 PORT OC3 POS MM
OSM-8OC3-POS MM
STATUS
1
1
2
2
3
3
1
2
3
4
4
4
RE
SET
LINK
CARRIER
ALARM
LINK
LINK
LINK
LINK
5
6
7
8
INPUT
OK
FAN
OK
OUTPUT
FAIL
OUTPUT 42V
42V
OK
I
IN
ST
AL
L
RU
N
O
110-120V - 15A
200-240V - 15A
60/50HZ
m
m
/
+
WS-C6500-NEB-FAN2
HIGH SPEED FAN
48V INPUT 1
RTN -48VDC GND
INPOUT POWER
GOOD
48V INPUT 2
RTN -48VDC GND
INPOUT POWER
GOOD
FAN FAIL