5-17
Cisco XR 12416 and Cisco XR 12816 Router Chassis Installation Guide
OL-17440-01
Chapter 5 Maintaining the Router
Removing and Replacing AC and DC Power Subsystem Components
To remove and replace an AC power supply, use the following procedure.
Step 1
Unplug the power supply cord from its AC outlet.
Step 2
Power off the circuit breaker assigned to that AC outlet.
Warning
To ensure that power remains off while you are performing this procedure, tape
the circuit breaker switch in the off (0) position.
Step 3
Remove the PEM from the power shelf (
Figure 5-10
):
a.
Loosen the captive screw to release the ejector handle.
b.
Pivot the ejector handle down to eject the power supply from its backplane
connector.
c.
Slide the power supply out of its bay while supporting it with your other hand.
Figure 5-10
Removing an AC Power Supply
Pwr Ok
Fault
Temp
OC
Pwr Ok
Fault
Temp
OC
129497
Pwr Ok
Fault
Temp
OC