Page 47
Instructions
In operation, coasting of basket increases, making it
necessary to readjust reversing timer.
CAUTION
Failure to do this will cause the thermal overload
units for the basket to cut-out unnecessarily
and probably damage the gear reducer.
Adjustment of Reversing Timer Dwell Time
CAUTION
Dryer power supply must be shut off before
adjusting timer.
The dwell time is the time from when the motor turns
off, to when it turns on again in the opposite direction.
Turning the dwell adjustment knob counter-clockwise
increases the dwell time and turning it clockwise
decreases the dwell time.
Recommended dwell time for the basket to stop completely
is 5 to 7 seconds. Minimum basket stopping time is
4 seconds.
NOTE
Select non-reversing or reversing before starting
dryer.
NOTE
Fan rotates counter-clockwise as viewed from
back end of motor. See arrow on motor support.
to change rotation, reverse power leads L1 and L2.