15
TS9000/TS9050 TouchStar Systems User Manual
that mates with a similar connector on the DC power
converter’s power input cable.
The BLACK harness wire is connected to a POSITIVE
voltage source. The WHITE harness wire is connected to the
NEGATIVE voltage source. The booted connector end of the
cable should be accessible for convenient attachment to the
DC power converter.
Make sure the DC power converter ON/OFF switch is in
the OFF position. Once the access cable is wired to the
electrical system, mate the connectors on the access cable
and the DC power converter power input cable. All cable
connections must be completed before applying power to
the TS9050.
12 V Power Converter:
The electrical harness access cable for the 12 V Power
Converter has three leads at one end which are permanently
wired into the vehicle’s electrical system. The leads are
WHITE and BLACK, plus a third lead that is either shield
braid or GREEN. The other end of the cable has a circular
3-pin connector with rubber boot that mates with a similar
connector on the DC power converter’s power input cable.
The BLACK harness wire is connected to a POSITIVE
voltage source. The WHITE harness wire is connected to the
NEGATIVE voltage source. The GREEN or braided lead is
connected to chassis ground. The booted connector end of
the cable should be accessible for convenient attachment to
the DC power converter.
Make sure the DC power converter ON/OFF switch is in
the OFF position. Once the access cable is wired to the
electrical system, mate the connectors on the access cable
and the DC power converter power input cable. All cable
connections must be completed before applying power to
the TS9050.
NETWORK CONNECTIONS
The TouchStar is factory-equipped with a network interface
and the appropriate network software for communicating with
the network. The physical network connection requirements for
hard-wired and wireless operation are provided below. The
network ports on the TouchStar use different connectors for
each type of network. For Token Ring connections, a DB9
INSTALLATION & MAINTENANCE - 2