<Watch Cannot be Switched to Another Mode from the Water Depth
Measurement Mode>
When there has been a pressure change of 1000 hPa or more with the water
sensor still activated by perspiration and so forth at a high altitude (such as in
an airplane) and barometric pressure changes occur in a short period of time,
the water depth measurement display may not return to 0.0 m after returning to
a lower altitude (earth), thereby preventing the watch from leaving the water
depth measurement mode.
When this happens, pull the crown out after loosening the screw to cancel the
water depth measurement mode. (Since the display of analog time becomes
incorrect when the crown is pulled out, make sure to reset the analog time
after performing this procedure.)
<Watch Exhibits an Abnormal Display or Operation>
If the watch is accidentally subjected to a strong shock or intense static electric-
ity, the display or operation of the watch may rarely become abnormal (such as
the digital display being incorrect or the alarm sounding continuously). When this
happens, perform the all-reset procedure as described in Section 23 “All-Reset”.
If the problem is still not resolved even after the all-reset procedure has been
performed, please consult your nearest Citizen Service Center.
81
21. Troubleshooting
<When the Second Hand Moves at Two-Second Intervals>
The low battery warning function is activated when the battery approaches the
end of its service life. Have the battery replaced promptly when this occurs.
<CHEk Remains Displayed for a Long Time>
It is possible that the water sensor is continuing to operate due to the presence
of sand, dirt, perspiration or other debris on the sensor. When this happens,
rinse off the debris with water and carefully wipe off any moisture with a dry
cloth.
<ER Remains Displayed for a Long Time>
• ER is displayed during use on land (excluding locations at an altitude of 4000
m or higher).
• ER remains displayed even when considerable time has passed after diving.
In the above cases, there is the possibility of a problem with the pressure sen-
sor. When this happens, discontinue using the watch and consult your nearest
Citizen Service Center.
80