fn=4: Function 4 Sending the Set Memory Switch Value
GS ( E pL pH fn a
[Code]
<1D>H<28>H<45>H<pL><pH><fn><a>
[Range]
(pL+pH×256)=2
fn=4
CT-S280
a=1, 2, 3
CT-S300
a=1, 2, 3, 4
CT-S281
a=1, 2, 3, 4, 5, 13
CT-S310
/
CT-S2000
/
CT-S4000
/
CT-P29x series
a=1, 2, 3, 4, 5
CT-S801(II)
/
CT-S851(II)
/
CT-S601(II)
/
CT-S651(II)
/
CT-S310II
/
CT-S251
/
CT-D150
/
CT-E351
/
CT-D1
51
/
CT-E651
a=1, 2, 3, 4, 5, 6
[Outline]
[The specification which is common to the model]
• Sends the content of MSW set in “a”.
Hex.
No. of Data
Header
37H
1
ID
21H
1
Data
30H or 31H
8
NULL
00H
1
• Sends the set value of data in 8-byte data raw in order of bits 8, 7, 6
OFF: 30H (“0”)
ON : 31H (“1”)
[Caution]
[The specification which depend on the model]
CT-S281
/
CT-S310
/
CT-S2000
/
CT-S4000
/
CT-P29x series
/
CT-S801
/
CT-S851
/
CT-S601
/
CT-S601
/
CT-S310II
/
CT-D150
/
CT-E351
• MSW7 to MSW10 cannot be sent by this command.
• Transmission is available by <Sending preset customize value>.
CT-S801II
/
CT-S851II
/
CT-S601II
/
CT-S651II
/
CT-D151
/
CT-E651
• MSW7 to MSW10,13 cannot be changed by this command. They can be changed by the
setting of customize value.
CT-S251
• MSW7 to MSW10,11,13 cannot be changed by this command. They can be changed by
the setting of customize value.