- 385 -
DLE DC4 fn m t
(Specification of fn = 1)
[Function]
Outputting specified pulse in real-time
[Code]
<10>H<14>H<fn><m><t>
[Range]
fn=1,
m=0, 1
1 ≤ t ≤ 8
[Outline]
[The specification which is common to the model]
• A signal specified with “t” is output to the connector pin specified with “m”.
m
Connector Pin
0
Pin No. 2 of drawer kick-out connector
1
Pin No. 5 of drawer kick-out connector
• Set the ON time/OFF time to t x100 ms, respectively.
[Caution]
[The specification which is common to the model]
• When receiving a code row coinciding with the code configuring this command, the
same operation as this command takes place and attention by the user is required.
Example: When corresponding code row is present in bit image data.
• This command must not be used between other command code rows.
Example: This command is used in the bit image data.
• This command is ignored under the following conditions.
• During sending block data
• During output of signal to drawer kick connector
• During occurrence of error
[See Also]