— 31 —
(1) Connector pin configuration
(2) Electric characteristics
1)
Drive voltage: 24 VDC
2)
Drive current:
Approx. 1 A max. (not to exceed 510 ms.)
3)
DRSW signal: Signal levels: “L” = 0 to 0.8 V, “H” = 2 to 3.3 V
(3) DRSW signal
DRSW signal status can be tested with the DLE+EOT, GS+a, or GS+r
command or at pin 34 on the parallel interface port.
(4) Drive circuit
No.
Signal
Function
1
FG
Frame ground
Connector used:
TM5RJ3-66 (Hirose) or
equivalent
Applicable connector:
TM3P-66P (Hirose) or
equivalent
2
DRAWER1
Cash drawer 1 drive signal
3
DRSW
Cash drawer switch input
4
VDR
Cash drawer drive power supply
5
DRAWER2
Cash drawer 2 drive signal
6
GND
Signal ground (common ground on
circuits)
CAUTION
Cash drawers 1 and 2 cannot be operated at the same time.
The solenoid used for the cash drawer should be 24
or more. Do not allow the
electric current to exceed 1 A. Excessive current could damage or burn out the
circuits.
Cash drawer kick-out connector
Cash drawer open/
close switch
Shielded
Cash drawer
Printer