ci5000 Series Printer Technical Service Manual
Version 0.1
9-9
Modulation Adjustment
1. Leave the Charge at 72 from the previous (Band) steps
2. Leave the Pressure at 40 from the previous (Band) steps
3. Using the [Edit]
button set the Band to new setting (found in the Band Adjustment sets)
4. Start at a Modulation of 240 by using the [Edit]
button to the right of Modulation and selecting
from the list and pressing [Save]
. Take a print sample as described in the previous step
by pressing the [Print Trigger]
button in the Function Tool Bar.
Advance the Modulation down to the next selection, wait 5 seconds, then take a print sample
after each adjustment.
Inspect each sample at each Modulation setting looking for print defects.
NOTE:
A 100 volt window is the minimum acceptable range (example 240-140)
5. If achieved, use the middle adjustment as the set point.
6. If not achieved, change the band setting (up or down) by 1 and retest.
Summary of Contents for ci5200
Page 34: ...ci5000 Series Printer Technical Service Manual Version 0 1 1 28 Ink System Diagram ...
Page 47: ...ci5000 Series Printer Technical Service Manual Version 0 1 2 10 ...
Page 129: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 6 Encoder ...
Page 130: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 7 Beacon Options ...
Page 132: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 9 ...
Page 189: ...ci5000 Series Printer Technical Service Manual Version 0 1 6 45 Pic 3 Pic 4 Ink Reservoir Low ...
Page 222: ...ci5000 Series Printer Technical Service Manual Version 0 1 6 78 ...
Page 286: ...ci5000 Series Printer Technical Service Manual Version 0 1 11 5 Electrical Connections ...
Page 287: ...ci5000 Series Printer Technical Service Manual Version 0 1 11 6 Fluids Connections ...