SYSTEM COMPLIANCE INFORMATION 

The QolorFLEX 3x10A Dimmer is ETL and cETL Listed as follows: 

ETL Listed, Conforms to UL 508A

cETL Listed, Certified to Can/CSA Standard 22.2 14-95

The QolorFLEX 3x10A Dimmer is CE & FCC Certified 

Standards Applied: 

BS EN 60950-1:2002 incorporating Corrigendum No. 1 and Amendment No. 1

 

EN 55203-1: 1996 

EN 55203-2: 1996 

Product Conforms to CE Marking Directive 93/68/EEC 

All QolorFLEX 3x10A Dimmer models are RoHS compliant 

Safety Notices 

Please read this entire manual before using your new equipment.  Please keep the 

manual in a safe place so you can refer to it in the future as required. 

The QolorFLEX 3x10A Dimmer is intended for use only by qualified professionals.  

Connection, installation and hanging of this equipment must be performed in 

accordance with all pertinent local, regional and national safety codes and regulations. 

QolorFLEX 3x10A Dimmer equipment is intended for indoor use only unless specified 

for outdoor use. 

Keep the equipment dry. Do not operate the equipment if it gets wet.

Do not operate in excessive heat/direct sunlight. 

Be sure installation provides adequate ventilation. Some system components can 

produce significant heat and must be properly installed to allow proper cooling and 

assure user safety (please see specific notes about QolorFLEX 3x10A Dimmer 

installation and heat in this manual).  All sides of the equipment must be clear of 

obstruction and allow free airflow. 

Page 3 

Summary of Contents for QolorFLEX 3x10A

Page 1: ...QolorFLEX 3x10A Dimmer 5620 User s Manual Rev 5 2017 City Theatrical Inc ...

Page 2: ... QolorFLEX 3x10A Dimmer 5 Controls Connections and Features 5 Front Panel 5 Back Panel 5 Menu System 6 Menu 7 Addressing 7 Level Tests 7 Curve Selection 7 RDM Basics 7 Figures Figure 1 QolorFLEX 3x10A Dimmer Front Panel 4 Figure 2 QolorFLEX 3x10A Dimmer Channel Dimmer 5 Figure 3 QolorFLEX 3x10A Dimmer Menus 6 Page 2 ...

Page 3: ...The QolorFLEX 3x10A Dimmer is intended for use only by qualified professionals Connection installation and hanging of this equipment must be performed in accordance with all pertinent local regional and national safety codes and regulations QolorFLEX 3x10A Dimmer equipment is intended for indoor use only unless specified for outdoor use Keep the equipment dry Do not operate the equipment if it get...

Page 4: ...erface Press the Enter center Button to access the menus and press the UP or Down Buttons to move through the menus When you reach a menu that you want to work in press Enter to select that menu and then use the UP or Down Buttons to move through that menu s options To scroll through a menu s selection options hold the Up or Down button When you reach an option that you want to modify press enter ...

Page 5: ...ixteen character display shows all of the Menu titles command options configuration data and other text and graphic data The backlight turns on whenever a button is pushed and turns off automatically after a preset time out The backlight off time out is adjustable via the Misc Control Button Pad This five button pad is the main control interface for the QolorFLEX 3x10A Dimmer The button functions ...

Page 6: ... Pass Thru Output When the Transmitter is connected to a conventional DMX controller this connector serves as a DMX pass thru DMX Termination Switch The QolorFLEX 3x10A Dimmer DMX Input is provided with a conventional manual termination switch Switch the handle to ON for end of line DMX Termination The Start Up display reports DMX connection status DMX OK or DMX No Data Press the center ENTER butt...

Page 7: ...work When RDM control activity is needed the controller will issue a special RDM data command to alert any connected RDM devices and then may issue any of a variety of other RDM commands to trigger actions or responses in the connected responders dimmers fog machines whatever As mentioned above the RDM data is mixed in with conventional DMX data and in theory should be invisible to conventional DM...

Page 8: ...ears the DMX512 Standard has required DMX devices to not respond incorrectly to data packets with alternate non 0 start codes there are units out there that completely disregard the start code which means they will do some strange things when presented with RDM data For these reasons we recommended that RDM users test their system well in advance of show time to identify any non compliant DMX devi...

Reviews: