background image

The 

QolorFLEX 3x10A

 Dimmer 

DMX Termination Switch

5PXLRF for DMX/RDM Pass Thru

5PXLRM for DMX/RDM Input

1x2 45A Anderson PowerPole

for DCV Input

3x2 45A Anderson PowerPole

for Dimmer Outputs

Reset Switch

Control Button Pad

LCD Display

5620 SHoW DMX

er

 3 Channel DImm

Figure 2, the 

QolorFLEX 3x10A 

Dimmer 

The QolorFLEX 3x10A Dimmer was designed to provide exceptional power and 

flexibility in a low voltage DC control unit.  It will operate with any DC voltage between 

9-24VDC.  Each dimmer channel can be separately configured with any of four different

output profiles, including ISL curve dimming (for incandescent loads), linear dimming,

LED dimming, or Non-Dim operation.  The unit may be configured either locally via the

Button pad and LCD user interface, or via RDM.

Controls, Connections

,

 and Features 

Front Panel 

LCD Display:  This two line by sixteen character display shows all of the Menu titles, 

command options, configuration data, and other text and graphic data.  The backlight 

turns on whenever a button is pushed and turns off automatically after a preset time-out.  

The backlight off time-out is adjustable via the Misc.  Control Button Pad:  This five-button 

pad is the main control interface for the QolorFLEX 3x10A Dimmer.  The button functions 

are UP, DOWN, LEFT/BACK, RIGHT/FORWARD, and ENTER. 

During normal operation (default configuration), the Left, Down, and Right Buttons serve 

as Bump Buttons for the three dimmers in the unit. 

Back Panel 

Anderson 45A Power Pole DC Power Input Connectors (Red +/Black -)  This is the 

+VDC power input for the QolorFLEX 3x10A Dimmer, and mates directly with 30A and

45A Anderson Power Pole connectors. The QolorFLEX 3x10A Dimmer is capable of

drawing up to 30 amps of DC power, so be sure that the connected input power wiring is

up to the task! 

Be sure the power connection is

 

polarized correctly

 before 

connecting

.

Page 5 

Menu (see below).

R

I

G

H

T

L

E

F

T

UP

DOWN

Summary of Contents for QolorFLEX 3x10A

Page 1: ...QolorFLEX 3x10A Dimmer 5620 User s Manual Rev 5 2017 City Theatrical Inc ...

Page 2: ... QolorFLEX 3x10A Dimmer 5 Controls Connections and Features 5 Front Panel 5 Back Panel 5 Menu System 6 Menu 7 Addressing 7 Level Tests 7 Curve Selection 7 RDM Basics 7 Figures Figure 1 QolorFLEX 3x10A Dimmer Front Panel 4 Figure 2 QolorFLEX 3x10A Dimmer Channel Dimmer 5 Figure 3 QolorFLEX 3x10A Dimmer Menus 6 Page 2 ...

Page 3: ...The QolorFLEX 3x10A Dimmer is intended for use only by qualified professionals Connection installation and hanging of this equipment must be performed in accordance with all pertinent local regional and national safety codes and regulations QolorFLEX 3x10A Dimmer equipment is intended for indoor use only unless specified for outdoor use Keep the equipment dry Do not operate the equipment if it get...

Page 4: ...erface Press the Enter center Button to access the menus and press the UP or Down Buttons to move through the menus When you reach a menu that you want to work in press Enter to select that menu and then use the UP or Down Buttons to move through that menu s options To scroll through a menu s selection options hold the Up or Down button When you reach an option that you want to modify press enter ...

Page 5: ...ixteen character display shows all of the Menu titles command options configuration data and other text and graphic data The backlight turns on whenever a button is pushed and turns off automatically after a preset time out The backlight off time out is adjustable via the Misc Control Button Pad This five button pad is the main control interface for the QolorFLEX 3x10A Dimmer The button functions ...

Page 6: ... Pass Thru Output When the Transmitter is connected to a conventional DMX controller this connector serves as a DMX pass thru DMX Termination Switch The QolorFLEX 3x10A Dimmer DMX Input is provided with a conventional manual termination switch Switch the handle to ON for end of line DMX Termination The Start Up display reports DMX connection status DMX OK or DMX No Data Press the center ENTER butt...

Page 7: ...work When RDM control activity is needed the controller will issue a special RDM data command to alert any connected RDM devices and then may issue any of a variety of other RDM commands to trigger actions or responses in the connected responders dimmers fog machines whatever As mentioned above the RDM data is mixed in with conventional DMX data and in theory should be invisible to conventional DM...

Page 8: ...ears the DMX512 Standard has required DMX devices to not respond incorrectly to data packets with alternate non 0 start codes there are units out there that completely disregard the start code which means they will do some strange things when presented with RDM data For these reasons we recommended that RDM users test their system well in advance of show time to identify any non compliant DMX devi...