background image

 

 

CG100SK

 

 

A

DAPTOR 

S

OCKET

 

U

SER 

M

ANUAL

 

 
 

 

 
 

CG100AS 

Adaptor Socket - UK

 

 
 
 
 
V

ERSION 

1.1 

21

 

F

EBRUARY

,

 

2020 

 

 

Disclaimers and Copyright 

Nothing contained in this publication is  to be  construed as granting any right, by implication or otherwise, for the 
manufacture,  sale,  or  use  in  connection  with  any  method,  apparatus,  or  product  covered  by  letters  patent,  or  as 
insuring anyone against liability for infringement of letters patent. 
Efforts  have  been  made  to  ensure  the  accuracy  and  reliability  of  the  data  contained  in  this  publication;  however, 
CityGrow Energy Systems Limited makes no representation, warranty, or guarantee in connection with this publication 
and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or from the use 
of any product or methodology described herein; for any violation of any federal, state, or municipal regulation with 
which this publication may conflict; or for the infringement of any patent from the use of this publication. Nothing 
contained in this publication should be viewed as an endorsement by CityGrow Energy Systems Limited of any particular 
manufacturer’s products. 
 
 
 

Summary of Contents for CG100SK

Page 1: ...bility of the data contained in this publication however CityGrow Energy Systems Limited makes no representation warranty or guarantee in connection with this publication and hereby expressly disclaim...

Page 2: ...near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat...

Page 3: ...1 Table of content 1 Introduction 1 2 Operation instruction 2 3 Pairing CG100SK with CityGrow s remote products 3 4 Specification 5...

Page 4: ...cially designed for CityGrow home automation system Description 1 ZigBee wireless remote control 2 Based on IEEE 802 15 4 3 2 4GHz radio frequency 4 Highly flexible 5 AC 220V 13 load UK Standard 6 LED...

Page 5: ...D Indicator 2 ON OFF Button 3 Cover Pull to remove MAIN UNIT FUSE CONN RESET 4 5 6 4 Reset Button 5 Programming Port 6 Fuse Press ON OFF Button once to toggle between ON and OFF LED ON indicates the S...

Page 6: ...and the other end to a PC STEP 2 The CG100AS must be programmed with an ID Refer to the User Manual for the instructions of the HomeNET Planner 2 software STEP 3 Unplug the USB Cable from the PC and...

Page 7: ...waiting confirmation of the binding process FUSE CONN RESET STEP 5 Press and release the desired ON OFF Button once to confirm the pairing FUSE CONN RESET STEP 6 The pairing process is complete NOTE T...

Page 8: ...Remote control ON OFF Range 100M line of sight ZigBee Mesh Network Operating temperature 0 C to 40 C Operating humidity 20 to 95 non condensing Unit Dimension L x W x D mm 97 x 69 x 62mm Storage 20 C...

Reviews: