Civemasa Implementos Agrícolas
19
CRO 4.0
Set-up instructions
• Lastly, couple the male quick couplers
to the hydraulic outlets of the tractor (double
command) and check if they are cleaned.
NOTE
For a faster equipment activation,
it is necessary to use a double
command, with four rear outlets.
NOTE The ideal level is when the
oil reaches the hole of the
level plug (E), being the
equipment in a flat place.
Use only high-quality SAE
90 oil.
The oil must not contain
detergent.
The oil capacity on the
gearbox is 4.85 liters.
Hydraulic outlet
Gearbox
The gearbox (D) must be inspected before the equipment starts to operate. If the oil
level is low, fill it up.
After the first 200 hours of operation, it is recommended to change the oil. This is
necessary because by this time the gearbox will get softened. Afterwards, the change can
be made every 500 hours. Verify the oil level in a flat place by loosening and removing the
level plug (E) until the presence of oil is noticed.
In order to carry out the whole change, drain all the oil by removing the drain plug (F)
(located in the lower part of the gearbox), breather plug (G) and level plug. Then, insert the
drain plug and replenish it through the breather plug until the oil leaks through the level plug.
When filling up, complete the gearbox with the same type of oil. If it is not possible,
remove the remainder old oil and replenish the
gearbox completely.
The breather plug must never be
replaced with a common bolt. Its function
is to avoid that any pressure is created
inside the gearbox.
D
D
F
F
E
E
G
G