No water flow out of fountain

No power to outlet – confirm cooler plug is
plugged into electrical outlet. Check if circuit
breaker or fuse has tripped or blown.

Wire disconnected from solenoid/push bar
switch – identify correct wires and place onto
solenoid or connect the push bar switches.

Solenoid or regulator valve defect – contact
CIVIQ to supply a replacement part.

14/05/2019

18

Summary of Contents for Elkay LVRC8WS2K

Page 1: ...Trouble Shooting Manual Preventative Maintenance Guide for Elkay LZS8WSS2K LVRC8WS2K 14 05 2019 1...

Page 2: ...ter to clean drinking solution products To remove external hard water stains or lime scale use a mild vinegar water mix Flush the internal system with a food grade citric acid if necessary Check insid...

Page 3: ...urns freely and there are no obstructions from other components Ensure proper ventilation by maintaining clearance from cabinet louvers to wall on each side of Cooler as specified in Installation Manu...

Page 4: ...screws on bottom cover panel Vacuum the condenser coils on Replace lower panel You should be able to shine a flashlight on the outside of the coils and see the beam inside when the coils are clean Exc...

Page 5: ...rifice with a small round file not over 1 8 3 mm diameter or small diameter wire CAUTION DO NOT file or cut orifice material Care must be taken not to damage the orifice s Water Flow Confirm proper wa...

Page 6: ...t for 10 C 5 To adjust turn screw clockwise for colder counter clockwise for warmer Remove 4 screws on bottom cover panel Cold control is mounted to the center of the bracket just under the upper shro...

Page 7: ...MPa to adjust rotate screw clockwise raise stream and counter clockwise lower stream Remove 4 screws on bottom cover panel The regulator is part of the solenoid mounted to the left of the bracket just...

Page 8: ...lter Replacement Step 1 Determine when your filter needs to be changed Green 100 filter life Yellow Water is safe to drink but has 10 life left Red Filter life is at 0 replacement required 14 05 2019...

Page 9: ...r Base Panel Shroud Remove the panel at the base of the fountain otherwise known as the shroud This can be done with a manual screwdriver to remove the four flat head screws under the filler that secu...

Page 10: ...type of piping or valve that connects to the wall behind the filler This indicates the filler s water source In order to remove the filter you ll need to first shut this source off to prevent any mes...

Page 11: ...remove the original Elkay EZH20 filter grab the top of the filter closest to the filler and give it a firm twist counterclockwise This should loosen the filter from the filler and allow you to fully r...

Page 12: ...the new Elkay 51300c replacement Filter remove the filter s red top Make sure to keep the now open portion facing up Next take the opened filter and push it up and into the filter housing space where...

Page 13: ...the filler s tap to activate the new filter Sometimes water pressure may cause an irregular flow This is nothing to worry about and should normalize on its own After running enough water through the...

Page 14: ...lastic portion directly above the filling area that covers the inside of the filler s upper portion Using a manual screwdriver remove the two screws located on either side of the head panel Lift the p...

Page 15: ...omatically change the filter indicator light from red to green Assuming you would also like to reset the bottle counter press the button down again until the display reads RST BCNT Push the button aga...

Page 16: ...drinking fountain and cap or tape those ends Reinstall the bottle filler into position Verify that the count has stopped Note The bottle filler will function fully with those wires disconnected Those...

Page 17: ...Erratic Water Flow Filter capacity has been reached replace water filter Elkay filter 51300C Cooler menu is set to coldest setting Adjust one button menu setting from Water T to Cold or colder settin...

Page 18: ...ctrical outlet Check if circuit breaker or fuse has tripped or blown Wire disconnected from solenoid push bar switch identify correct wires and place onto solenoid or connect the push bar switches Sol...

Page 19: ...ctive Alternatively clean dirt debris off condenser as it may clog operation Fan is not running compressor is hot Ensure the fan blade is free from obstruction Replace fan motor if defective Ensure fa...

Page 20: ...ller Water is coming out of fountain but not from bottle filler Ensure the evaporator is pressurized Ensure IR sensor board is plugged in Check connection and press together firmly Ensure Solenoid wir...

Page 21: ...ndenser Condenser Out in Cap Line Suction Back to Compressor Condenser Fan Cooled Compressor R134a Evaporator Tube on Tube on Tank Heat Exchanger Suction and Cap line Bonded Drier Refrigeration System...

Page 22: ...Plumbing System 3 8 Water In Evaporator Strainer Solenoid Valve Bubbler Regulator 14 05 2019 22...

Page 23: ...If you have any other queries please contact CIVIQ on 1300 600 300 or email sales civiq com au 14 05 2019 23...

Reviews: