PROXIMA STX
Ice-Cream Cabinet
ENGLISH
14
WARNING:
During working operations, there is an air exchange between the cabinet’s refrigerating
system and the surrounding environment. For this reason don’t install the cabinet in
ambient subjected to pollution or having atmospheres with substances in concentration
or quantity out of the limits regulated by actual law for health care.
3.4
CANALIZATION
Before performing canalization check that the showcases are at the same height by
adjusting the special feet and that both showcases are laid flat, i.e. horizontally levelled.
In order to join two cabinets follow instructions below referring to picture n.7:
•
introduce the A pin and block it through the B dowels;
•
screw the E peg;
•
introduce the F and L plates and fix them through the dowels;
•
introduce the G crystal shoulder into the corresponding seating;
•
place the showcases side by side, till the E peg already screwed in the showcase, and
the F plate are perfectly introduced into the other showcase’s seatings, after screwing
the other dowel first;
•
introduce the C plate into the corresponding seating and block it with the D screw;
•
Insert divider glass G in its hole between the two cabinets.
Pic.7
Summary of Contents for FB Proxima STX A30
Page 1: ...Proxima STX gelateria English ...
Page 38: ......