PROXIMA STX
Ice-Cream Cabinet
ENGLISH
16
Respect national regulations for electrical installations.
Position the master switch in the OFF position.
The display cabinet is supplied with a 5-wire cable;
•
Yellow/Green = Grounding wire
•
Blue = Neutral Line
•
Brown = phase 1
•
Grey = Phase 2
•
Black = Phase 3
WARNING:
Never cut or remove the yellow-green cable mentioned above.
The five power supply wires must be connected to the back-bone network, which a san
efficient earth system, in compliance with national and local regulations (where present)
regarding electrical installations and suitable for the electric absorption of the display cabinet,
refer to chapter 2 – Total Absorbed Power.
WARNING:
The electrical connection to the mains must be made using the five wires supplied.
Moreover, the central plant to which the display cabinet is connected must have a
switch with contact opening of at least 3 mm protected by fuses.
WARNING:
Apply a suitable method of fixing to the power supply cable on the connection box,
making reference to the table shown below.
Rated Current
[A]
Rated Section [mm
2
]
Gen. Purpose Flex
Cables [mm
2
]
Grounding Cables [mm
2
]
3
0,5 ÷ 0,75
1 ÷ 2,5
3 ÷ 6
0,75 ÷ 1
1 ÷ 2,5
6 ÷ 10
1 ÷ 1,5
1 ÷ 2,5
10 ÷ 16
1,5 ÷ 2,5
1,5 ÷ 4
16 ÷ 25
2,5 ÷ 4
2,5 ÷ 6
25 ÷ 32
4 ÷ 6
4 ÷ 10
32 ÷ 40
6 ÷ 10
6 ÷ 16
40 ÷ 63
10 ÷ 16
10 ÷ 25
3.7
WATER DRAIN PIPE
If the cabinet is supplied with external drains for condensation / defrosting or periodic
cleaning water discharge, be sure to connect the drain pipes to the sewer.