PROXIMA STX
Ice-Cream Cabinet
ENGLISH
31
2)
The defrosting water does not drain off properly (that is, the water obtained from the melting
of ice during the automatic or manual defrosting phases).
Probable Cause
Probable Solution
The defrosting water drainage tube that goes
from the cold tub to the tub in which such
water is channelled (for evaporation) is blocked.
Open up the drainage tube
The display cabinet is positioned on the ground
in such a way that the drainage water is not
directed towards the outlet hole.
Ensure that the display cabinet is level on the
ground. It must be completely level.
3)
The compressor never stops or it works for very long periods of time.
Probable Cause
Probable Solution
The room temperature is very high (e.g. above
+32°C).
If it is not possible to lower the room
temperature (e.g. by means of air conditioning)
the compressor will work almost constantly.
The air condenser is blocked
Clean the condenser
The thermostat is set too low.
Regulate the thermostat to a higher
temperature
The ventilators are off.
Call the assistance service to individualise the
cause and replace them if necessary.
4) The display cabinet does not work
Probable Cause
Probable Solution
The cabinet is not plugged in.
Plug it in
The trip switch has gone off.
Reinsert the trip switch.
The general switch of the display cabinet is off.
Turn on the general switch of the display
cabinet