Troubleshooting
24
8.1.2.
Water reserve alarm
The level of demineralised water in the generator has fallen below the minimum
level.
To shut off the alarm, press function key
.
• Fill the external tank with demineralised water
NOTE: this alarm is initially displayed as a WARNING, and production continues
for a few minutes. If the water reserve condition persists, the alarm becomes
GENERATION STOP, with shutdown of gas production.
8.1.3.
Condensation drain failed alarm
The automatic condensate drainage procedure in the generator has not been
completed correctly.
This may occur when the generator is started up after a prolonged period of di-
suse.
To shut off the alarm, press function key
.
• Perform the shutdown and restart procedures several times (maximum 4) as de-
scribed in sections 6.5.1 and 6.2.
• If the alarm persists, contact Claind technical assistance.
8.1.4.
Drier lifetime expiring alarm
The estimated lifetime of the drier material has expired.
To shut off the alarm, press function key
.
The generator continues production but maintenance is recommended (drier re-
placement) as described in section 7.3.
To reset the counter related to this maintenance operation, refer to section 7.1
8.1.5.
Ordinary maintenance suggested alarm
More than 10,000 hours of operation have passed since the last general ove-
rhaul.
To shut off the alarm, press function key
.
The generator continues production but a general overhaul is recommended as
soon as possible, to be performed by a specialised CLAIND technician.
To reset the counter related to this maintenance operation, refer to section 7.1
8.1.6.
Incorrect switch off alarm
For details, refer to section 6.5.2.