Schedule Enable  Range: Y or N 

 

 

 

Default: Y

  

When enabled, the local thermostats scheduler function is enabled.  

 
Recovery enable  Range: Y or N 

 

 

 

Default: N 

For Heat Pump Systems.  Intelligent setback recovery is an automatic advance start of 
heating to allow the system to be at setpoint by the schedule time, without the use of Aux 
heating. 
 

Delta Settings

 : The Delta T Setting is the delta, or difference between, the setpoint and 

current temp for determining when a heat or cool call comes on.   
The “delta” is the number of degrees away from setpoint

 

H/C Delta

  

Range: 3 - 15 degrees.   

 

 

Default: 3F (1C) 

Sets the minimum separation between heating and cooling setpoints.   
Attempts to lower the cooling below the heating setpoint by this amount will PUSH the 
heating setpoint down to maintain this separation.   
 
Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling 
setpoint up to maintain this separation. 
 

Fan Purge 

Range: 0, 30-120 seconds 

 

 

Default: 0 (off) 

 

Heating Delta Stage 1 ON

    Range: 1 to 8 degrees 

 

Default: 1 

Sets the delta from setpoint that stage 1 heating starts. 
 

Heating Delta Stage 1 OFF

    Range: 0 to 8 degrees 

 

Default: 0 

Sets the delta from setpoint that stage 1 heating stops.  
Stage 1 turns off at se Delta Stage 1. 

 

Heating Delta Stage 2 ON 

Range: 1 to 8 degrees 

 

Default: 2 

Sets the delta from setpoint that stage 2 heating starts. 

 

Heating Delta Stage 2 OFF

    Range: 0 to 8 degrees 

 

Default: 0 

Sets the delta from setpoint that stage 2 heating stops.  
Stage 2 turns off at se Delta Stage 2. 

 

Heating Delta Stage 3 ON

   Range: 1 to 8 degrees 

 

Default: 3 

Sets the delta from setpoint that stage 3 heating starts. 

 

Heating Delta Stage 3 OFF

    Range: 0 to 8 degrees 

 

Default: 0 

Sets the delta from setpoint that stage 3 heating stops.  
Stage 3 turns off at se Delta Stage 3. 

 

Cooling Delta Stage 1 ON

 

Range: 1 to 8 degrees  

 

Default: 1

 

Sets the delta from setpoint that stage 1 cooling starts. 

 
Cooling Delta Stage 1 OFF

    Range: 0 to 8 degrees 

 

Default: 0 

Sets the delta from setpoint that stage 1 Cooling stops.  
Stage 1 turns off at setpoint - Delta Stage 1 

 

Cooling Delta Stage 2 ON

   Range: 1 to 8 degrees  

 

Default: 2 

Sets the delta from setpoint that stage 2 cooling starts. 

 
Cooling Delta Stage 2 OFF

    Range: 0 to 8 degrees 

 

Default: 0 

Sets the delta from setpoint that stage 2 Cooling stops.  
Stage 2 turns off at setpoint -Delta Stage 2. 

 

Summary of Contents for CH-THSTAT-W

Page 1: ...THSTAT W and will assist in trouble shooting the installation if needed CAUTION The typical wire colors noted below may be different from your installation Standard HVAC System Wiring Thermostat Term...

Page 2: ...TW45 Ver 02 04 01 WiFi Radio Version 02 30 System Type Standard Fan Type Gas Network Address 1 Status Press the MENU button to go to the main menu screen Scroll down to the Thermostat Info using down...

Page 3: ...Elec Fan Type Gas 2nd Stage Heat N 2nd Stage Cool N Done If HVAC system is a Standard Gas or Electric heat system Set the Type Standard Gas Electric systems or HP systems Set the Fan Type Gas or Elect...

Page 4: ...on a live system Network Settings Submenu Shows WiFi settings Same as in the Main Menu selection See Operations Manual System Settings Submenu Sets the HVAC operational settings below Mechanical Setti...

Page 5: ...at stage 1 heating starts Heating Delta Stage 1 OFF Range 0 to 8 degrees Default 0 Sets the delta from setpoint that stage 1 heating stops Stage 1 turns off at setpoint Delta Stage 1 Heating Delta Sta...

Page 6: ...g cooling cycle can begin Provides compressor short cycle protection Fan Cycler The fan cycler function cycles the HVAC system fan for an ON period followed by an Off period continuously Used to provi...

Page 7: ...1 On 1 8 1 Cool Delta Stage 1 Off 0 8 0 Cool Delta Stage 2 On 1 8 2 Cool Delta Stage 2 Off 0 8 0 Max Heat SP 40 109F 4 42C 90F Min Cool SP 44 113F 6 45C 60F Min Run Time 1 9 min 3 Min Off Time 1 9 mi...

Page 8: ...o Elec for electric heat fan call with heat call 3 2nd Stage Heat Enable second stage heating outputs If you have a single stage heating system leave this set to N If you have a 2 stage heating system...

Page 9: ...the correct system operation For change over with cool systems Orange wire O terminal set C O type to w cool most common and default setting For change over with heat systems Brown wire B terminal se...

Reviews: