Page 11 -G1100 Installation Manual
on the proper wire to unlock the vehicle’s doors. By programming the system for double pulse door unlocking, these systems
can be interfaced directly without the use of relays or any additional circuitry.
4.
Door Lock Pulse Width.
Selects between a 1-second and a 4-second output for door locking and unlocking. Set to 4
seconds when interfacing into vehicles equipped with vacuum door locking systems.
5.
Passive Locking.
Selects whether or not the system will automatically lock the doors with Auto Rearm and Passive Arming.
6.
Door Entry Delay with Passive Arming.
When selected, the door input trigger will be delayed for 15 seconds, allowing
access to the emergency override switch. Only delays when the system is armed passively.
7.
Ignore Dome Light Delay.
For use with vehicles equipped with a timed dome light circuit that stays on after the door has
been closed. When programmed ON, the open zone indication function will ignore the door zone.
8.
Auto Rearm.
When selected, the system will automatically rearm if no other activity is detected within one minute of Remote
Disarming.
One minute after Remote Disarming, the system will alert you with a 10 second series of chirps, then arm. (If the Passive
Door Locking feature is selected during the installation, the system will also relock the doors.)
Any of the following will cancel Automatic System Rearming:
• Turn on the ignition.
• Activate the Auxiliary Function.
• Open the Trunk or Hood.
Automatic System Rearming is independent of Passive Arming and only takes place if the system was Armed (actively or
passively) for at least 15 seconds and then Disarmed by the Remote Transmitter.
9.
Horn Honk / Arming Output.
Selects between pulsed or constant output for the Brown/White wire.
10.
Trunk Disarm Feature.
When selected, this feature will automatically disarm the alarm when the auxiliary 1 function (trunk)
is activated.
11.
Siren / Horn Chirps.
When set for Horn Chirps, the horn will honk when arming and disarming allowing the siren to NOT
be installed.